Titration finds an unknown concentration by reacting a solution against one of known strength. The method, the endpoint, and the calculation that follows.
A titration answers the question analysis asks most often: how concentrated is this solution? A measured volume of the unknown is placed in a flask, and a solution of known concentration is run in slowly from a burette until the reaction between them is exactly complete. An indicator, a dye that changes colour at the right point, or a pH probe shows when that moment, the endpoint, has arrived. Repeating the titration and averaging the consistent results, called concordant titres, removes the effect of any single misjudged drop. The whole method rests on knowing the volumes and one concentration very precisely.
The balanced equation converts the titration volumes into the unknown concentration. Suppose 25.0 millilitres of sodium hydroxide solution need 20.0 millilitres of 0.100 molar hydrochloric acid, and the equation shows the two react one to one. The acid used contains 0.100 x 0.0200, which is 0.00200 moles, so the flask held 0.00200 moles of hydroxide in 25.0 millilitres, a concentration of 0.0800 molar. When the equation has different proportions, such as two hydroxides per sulfuric acid, the mole ratio scales the answer, which is why the equation must be written before any numbers are touched. The titration calculator on the tools page handles the ratio for you.
An indicator must change colour at the pH the mixture has at the endpoint, which depends on the strengths of the acid and base involved. Methyl orange suits a strong acid against a weak base; phenolphthalein suits a weak acid against a strong base; a strong acid with a strong base gives a steep pH jump that almost any indicator catches. The classic errors are reading the burette from the top of the meniscus instead of the bottom, leaving an air bubble in the burette tip, and overshooting the endpoint with a heavy hand near the end. Drop by drop, with swirling, is the whole secret. A final distinction is worth fixing firmly. The equivalence point is the exact moment the moles match the equation's ratio; the endpoint is the moment the indicator changes colour and you stop the burette. Good titration design makes the two coincide as closely as possible, but they are not the same thing, and the small gap between them is a genuine source of error. Choosing the indicator for the strengths of acid and base involved, as described above, is how the gap is kept to a fraction of a drop, and rinsing the flask walls near the end washes the last traces of solution into the reaction where they belong.
The calculator that goes with this guide is ready on the tools page.
Open the titration calculator